Chicago Window Expert Nobody knows more about windows.
  • Low-E Glass for Cooling Loads

    By Mark Meshulam

    Mark Meshulam is an expert witness and consultant for glass, windows and building facades.

    The previous post focused on how Low-E glass reduces the loss of room-side heat by reflecting long-wavelength infrared radiation back into the room. This would be typical of a Chicago-based dude who hasn’t seen much sun since last September.
    Northerners (us) vs Southerners (them)
    Nonetheless, your Chicago Window Expert recognizes that there are folks out there much smarter than he, who live in climates basking in sunlight, where beautiful bronzed people roam, where bikini budgets exceed that of sweaters, where tanning oil is consumed the way we Northerners consume heating gas. Such people should be flogged! But I’m not jealous.

    As my friend Solomon from LA once said to me, smiling a goofy grin as we bicycled along Santa Monica beach among throngs of burnished pagans, “Nothing of importance was ever accomplished in a warm climate”. Take that!

    To show my equanimity toward our sun-baked brethren, today I will focus on the use of Low-E glass in controlling cooling loads. When I refer to cooling loads, I mean the exterior heat and sunlight which warm our buildings and cause us to spend lots of money running the air conditioning. Obviously our sun worshippers in the South pay dearly for their sunlight, but even we in the Northlands suffer many a hot and sticky day in the summer and our AC units run furiously.

    A lesser known fact is that in our Northern downtown office buildings, cooling loads are much more of a cost than are heating loads. This is due to the way one of my favorite ratios, the surface area to volume ratio, plays out as buildings get bigger.

    One of the biggest factors for the ability of any object (including living creatures) to dissipate its heat is the ratio of that object’s surface area to its volume.

    Geometry question: what geometrical shape has the lowest surface area in relation to its volume? Answer: a sphere. As buildings, or people approach a spheroid shape, or have a larger footprint, they lose surface area as a percentage of their volume.

    Surface area is needed to radiate heat away from the object. the less area, the harder it is to dissipate heat. A close to home example:

    Gomer Pyle’s famous backhanded compliment to a Rubenesque lovely, “For a fat girl you sure don’t sweat much!”

    Large buildings are the fat girls and boys of construction. Even in cold weather, they have trouble dissipating heat. The fact that we insulate more now than ever before exacerbates the heat dissipation issue. Throw in the fact that office buildings run lots of heat-producing equipment and house gaggles of warm-bodied junior executives, and you have a formula for a big cooling cost.

    A well chosen Low-E glass will contribute to the solution by reflecting away heat energy before it can enter the building, and by possibly allowing interior radiant heat to escape.

    Manufacturers of Low-E glass and coatings have developed products which are contoured for warmer climates or larger buildings. One of the tricks here is to create the product that also allows good light transmission and does not look like a mirror.

    The Oz-like appearance of the Dallas Skyline is due to the heavy use of reflective glass

    The Oz-like appearance of the Dallas Skyline is due to the heavy use of reflective glass


    Many cities – take Dallas for example – have struggled with solar heat gain for decades. For decades their response was to build buildings with great expanses of highly reflective curtainwalls, giving the skyline a unique glistening appearance. But there were two downsides: adjacent buildings were blasted by the reflections, and interior views were dimmed by thick glass coatings and colorations.

    A more current trend is to work toward balancing the loss of visible light with the need to reflect heat, while also getting away from the mirrored look. Each year more is accomplished in these areas. Major players in this field in the USA market are PPG, Guardian, Viracon. Next week, we will talk with all of them and hear not only their solutions, but where we are all going with energy and windows in the future.

    Mark Meshulam, Chicago Window Expert, at jobsite in summer in Chicago

    Mark Meshulam, Chicago Window Expert, at jobsite in summer in Chicago


    Are you loaded with cooling costs?
    No matter where you are,
    contact me, Mark Meshulam,
    the Chicago Window Expert
    For the expert attention you deserve
    Mark@ChicagoWindowExpert.com
    Download Brochure
    Download Mark Meshulam’s CV
    Download Field Testing Credentials

    Current client locations:
    Alabama, Alberta, Arizona, Arkansas, British Columbia, California, Colorado, Connecticut, Florida, Georgia, Hawaii, Illinois, Indiana, Iowa, Japan, Louisiana, Maryland, Massachusetts, Michigan, Minnesota, Missouri, Montana, Nebraska, New Jersey, New York, North Carolina, Nova Scotia, Ohio, Oklahoma, Ontario, Oregon, Pennsylvania, Russia, Singapore, Tennessee, Texas, Utah, Virginia, Washington State, Washington DC and Wisconsin.
    Coming soon to your area!

    2 Comments

2 Responses to “Low-E Glass for Cooling Loads”

  1. I am doing well, thank you, Mark.

  2. Hey! I’m famous! You quoted me! And I’m even right next to that
    bikini babe!
    My E rating is rising exponentially!

    Let me know when you start doing solar in California. I’ll be your
    first customer.

    Sol

Leave a Reply

*

Generic selectors
Exact matches only
Search in title
Search in content
Search in posts
Search in pages
Filter by Categories
About windows & glass
Accident investigation
Aluminum windows
architecture
Bad replacement windows
Bad window installation
Bad window replacement
Best windows
Broken glass evidence
building design
Building Energy Benchmarking
Building envelope
Building science
caulking contractor
Construction defects
Curtainwall retrofit
Drafty windows
Energy Efficient Windows
Expert witness
Exterior facade consultant
falls from windows
Fiberglass windows
Glass
Glass breakage
Glass evidence
Glass Safety
Glass types
Introduction
leaks in walls
masonry
Mockup testing
mold in walls
My windows leak
Nickel sulfide inclusion
personal injury
Preconstruction mockup testing
PVC windows
Renewable Energy
Repair or replace windows?
Replace weatherstripping
Restoring windows
Safety glass
Safety glazing
Secondary glazing
Shower doors
Shower enclosure
solar energy
Solar Power
Spontaneous glass breakage
Steel windows
Testing windows and glass
The Construction Process
Types of glass
Vinyl windows
Web statistics
Window air infiltration
Window air leaks
Window condensation
Window dangers
window falls
Window gaskets
window replacement
Window retrofit
Window safety
Window test
Window testing
Window types
Window water leaks
Window weatherstrips
Windows and Energy
Windows leak
Wood windows
Wynn Hotel
NEW: Caulking, Tuckpointing and Window Heaters
Now offering caulking, tuckpointing and waterproofing services. We also have a system to heat windows and reduce or eliminate condensation. Contact mark@chicagowindowexpert.com
for details
Contact us!

No matter where you are,
Chicago Window Expert can help you
Mark Meshulam
Email me               CV-Resume'
Brochure      Testing Credentials
Follow us on Facebook or Twitter
for updates you won't see here
View Mark Meshulam's profile on LinkedIn

Locations

Alabama, Alberta, Arizona, Arkansas, British Columbia, California, Colorado, Connecticut, Florida, Georgia, Hawaii, Illinois, Indiana, Iowa, Japan, Louisiana, Maryland, Massachusetts, Michigan, Minnesota, Missouri, Montana, Nebraska, New Jersey, New York, North Carolina, Nova Scotia, Ohio, Oklahoma, Ontario, Oregon, Pennsylvania, Russia, Singapore, Tennessee, Texas, Utah, Virginia, Washington State, Washington DC and Wisconsin

Coming soon to you

Photo of the day

h06-look-for-leaks.jpg
Witnesses and lab tech are inside the chamber during the water test, looking for leaks.