Aug25
The Dynamic Water Test
Laboratory and field testing are an important – some would say integral – part of the window business, both in the realms of product certification for individual window units and also for the prove-out of full assemblies.1 CommentFor product certification such as AAMA and NFRC, specific-sized windows are placed in test chambers and tested using methods and criteria which are according to an organized set of performance levels.
For testing of larger scale custom construction, however, there is little that is truly standard from one test to the next.
The Architect or Consultant designs a test specimen and selects test methods and criteria specifically for each project.
This specimen is then tested in specialized laboratories, such as the Construction Research Laboratory in Miami, Mid America Testing in Catawissa, MO, or Quast Consulting & Testing in Mosinee, WI.
The test specimen, or mockup, is often designed to be a representative sampling of conditions found on the project, bringing together as many unique features of the wall construction (such as fixed, operable, sliding doors, swing doors, inside and outside corners) into one assembly as is feasible.
We, the window contractor, then create a full set of shop drawings for the mockup. When approved, the mockup is released for fabrication and a custom sized chamber is built in a test facility. Then, with material, drawings and tradesmen, we go to the lab, build the mockup, and test it.The amount of attention, effort, work and expense involved in mockup tests make them seem almost like a job unto themselves.
Building a typical window mockup often takes about a week, but a complex assembly such as Avenue East’s mockup took much longer due to the size and composite nature of the assembly. Testing can also take one week or many.
The beauty of building a mockup is having the ability to really study unique conditions and make adjustments before going into production.
A mockup also gives design professionals and owners a chance to see a piece of their building many months before it will be built in its ultimate location.If problems arise in the testing, delays and redesigns can result. I have seen full mockups torn down and replaced if fundamental problems arose in the testing.
As surprising as this may seem, it is infinitely better than erecting a building and then discovering its fatal flaw after it is completed.
One of the most exciting aspects of laboratory testing of custom wall assemblies is the dynamic water test. It combines huge volumes of water with high, buffeting winds delivered by none other than an airplane engine!
If your specimen passes this test, you should have a very good product indeed!
Now you can be inside the test chamber during the dynamic water test. Watch our video:
Need to discuss testing for your project?
Contact me, Mark Meshulam,
the Chicago Window Expert
for the expert attention you deserve.My phone: 847-945-9200 ext 229
My email: mark@chicagowindowexpert.comSubscribe to Chicago Window Expert
One Response to “The Dynamic Water Test”
-
The windows are elegant. You surely planned it very well.
A water feature will fit to add more attraction. The elegance and beauty will surely predominate.
Leave a Reply
Posts
- Leaks Through Split Face Block
- Storm Damage to Windows and Glass
- Bill Baker of Skidmore, Owings & Merrill LLP: Tall Buildings and the Burj Khalifa
- Fixing Window Leaks in Tall Buildings
- Designing Buildings for the Very Windy City
- An Interview with Historic Mike Jackson
- Historic Window Renovation
- 2009 Web Statistics Revealed!
- Window Condensation: Top 10 Fixes
- Chicago Energy Conservation Code for Dummies
- Thermal Images of Insulated Glass Types
- Does Chicago Code Require Low-E Glass?
- Wynning in Glass Vegas
- Drowning Worms? An Olympic Eulogy
- Field Museum Window Replacement
- CWE Visits Solar Power Plant
- Legal Claims and Disputes in Construction
- The Dynamic Water Test
- An Interview with Guardian
- An Interview with Viracon
- The Future of Windows
- News from the Green Front
- Chicago Window Expert Goes Solar
- An Interview with PPG
- Fine Tuning Low-E Glass
- Low-E Glass for Cooling Loads
- The Lowdown on Low-E Glass
- Diagnosing Glass Breakage
- Annealed, Heat Strengthened, Tempered and Insulated Glass
- Curtainwall Leaks
- Window Glazing Leaks
- Wood Window Leaks
- Aluminum Window Leaks
- Window Sealant Failure
- Keying for Window Leak Survey
- Documentary Photos for Curtainwall Survey
- Performing Window Survey
- Documentary Photos for Window Survey
- Creating a Leak Survey Form
- Preparing for a Window Leak Survey
- My Windows Leak!
- Window Repair or Window Replacement?
- Welcome to Chicago Window Expert
Most Popular Posts
My Windows Leak! 30 comment(s) | 4201 view(s)
Window Glazing Leaks 16 comment(s) | 2498 view(s)
Aluminum Window Leaks 3 comment(s) | 1328 view(s)
Annealed, Heat Strengthened, Tempered and Insulated Glass 5 comment(s) | 1141 view(s)
Window Condensation: Top 10 Fixes 6 comment(s) | 952 view(s)
Tax Credit 0 comment(s) | 929 view(s)
Window Sealant Failure 13 comment(s) | 878 view(s) An Interview with Viracon 3 comment(s) | 869 view(s)
GGP 0 comment(s) | 763 view(s)
Preparing for a Window Leak Survey 2 comment(s) | 758 view(s)
Diagnosing Glass Breakage 11 comment(s) | 704 view(s)
Bill Baker of Skidmore, Owings & Merrill LLP: Tall Buildings and the Burj Khalifa 4 comment(s) | 679 view(s)
About 0 comment(s) | 673 view(s)
Historic Window Renovation 5 comment(s) | 607 view(s)
2009 Web Statistics Revealed! 3 comment(s) | 573 view(s)
An Interview with Guardian 4 comment(s) | 565 view(s)
Curtainwall Leaks 6 comment(s) | 555 view(s)
Chicago Energy Conservation Code for Dummies 5 comment(s) | 542 view(s)
Welcome to Chicago Window Expert 4 comment(s) | 541 view(s)
An Interview with Historic Mike Jackson 2 comment(s) | 456 view(s)








Recent Comments