Mark Meshulam is an expert witness and consultant for windows, glass and building exteriors.
Mike Marsiglio writes…I was hoping you can help me with this as the Chicago Conservation code book is very confusing to me.
I am in process of purchasing a new condo that was built in 2008. During the home inspection, it was found that the sliding glass doors contain Low E coating but the bedroom windows do not (all of the unit faces East).
My inspector thought that the Chicago Energy Conservation Code mandates all new construction to have Low E coating on the windows. Do you know what the ruling is on this by chance?Mark Meshulam responds…
Since I am the Chicago Window Expert and I know everything about windows, I shrewdly decided to defer this tricky question to Patrick Loughran FAIA, PE, LEED AP and Randy Chapple AIA, SE, CSI (former President), CCS, LEED AP, both Associate Principals at Goettsch Partners. If you did not already figure out from the number of initials following their names that these Architects are highly educated professionals, then take my word for it. They and their firm, Goettsch Partners are among the very best Chicago has to offer, and Chicago is world-renowned for our architects. See their website here.Patrick and Randy respond…
We agree that Chicago’s Energy Conservation Code is difficult to understand; however we will make an attempt at answering Mike’s question. There are two ways for a new glass façade to pass the “Chicago Energy Conservation Code” :
1) Acceptable Practice Method:
For Commercial Design, if your façade is less than 40% glass, the glass properties used on the building facade must meet a minimal performance level. This is the “prescriptive” method. Based on your glass percentage, in most cases where clear glass is used, you will need to use a low-e coating in order to meet the minimum Solar Heat Gain Coefficient (SHGC) requirements described in the code; however if you have between 10-25% glass on the building, it is possible to use a tinted glass that has no low-e coating and still meets the minimum SHGC required by code.
For Residential Design using the “prescriptive” method, only the Glazing U-factor weighs in on the selection of the glass. In this case the SHGC, which is related to the use of low-e coatings, is not considered.The second method is:
2) Total Building Performance Method:
For commercial as well as residential design, designers can use a computer analysis method, for example “COMcheck“, to verify the enclosure (roof and all exterior walls) as a whole passes the minimum energy performance required by code.
In this method, glass without a low-e coating could be used in some areas of the building, and the overall façade/enclosure could pass the Chicago’s Energy Conservation Code. The best example of this can be seen in high rise building construction in the city. The typical high rise curtain wall glass has a low-e coating; however the lobby level glass is typically monolithic with no low-e coating.In summary: There is nothing requiring a project to have low-e coating with either method. It all depends on how much glass you have on the building, what type of glass is applied and which method you use. To the best of our knowledge the only place that Low E coatings are required by the Chicago Energy Conservation Code only applies to buildings that rely on renewable energy. Otherwise the requirements are based on the performance standards listed above.
We hope that helps. Good luck.
Patrick Loughran
and
Randy Chapple
For building envelope enthusiasts,
I recommend two excellent books
written by Patrick Loughran:
Falling Glass: Problems and Solutions in Contemporary Architecture
Failed Stone: Problems and Solutions with Concrete and Masonry
Need a referral to an Architect or Engineer?
Read the rest of this entry »
Most Popular Posts
- My Windows Leak!: 44 comment(s) | 15549 view(s)
- Window Glazing Leaks: 19 comment(s) | 6537 view(s)
- Aluminum Window Leaks: 7 comment(s) | 4056 view(s)
- Preparing for a Window Leak Survey: 2 comment(s) | 3181 view(s)
- Leaks and Problems with Vinyl Windows: 10 comment(s) | 2795 view(s)
- Window Sealant Failure: 17 comment(s) | 2715 view(s)
- Window Condensation: Top 10 Fixes: 10 comment(s) | 2681 view(s)
- Annealed, Heat Strengthened, Tempered and Insulated Glass: 6 comment(s) | 2616 view(s)
- Diagnosing Glass Breakage: 23 comment(s) | 2573 view(s)
- Bill Baker of Skidmore, Owings & Merrill LLP: Tall Buildings and the Burj Khalifa: 4 comment(s) | 1470 view(s)
- Testing Leaking Brick Walls: 15 comment(s) | 1421 view(s)
- Insulated Glass Seal Failure: 16 comment(s) | 1407 view(s)
- An Interview with Viracon: 4 comment(s) | 1164 view(s)
- Leaks Through Split Face Block: 6 comment(s) | 1156 view(s)
- The Lowdown on Low-E Glass: 3 comment(s) | 1138 view(s)
- Curtainwall Leaks: 6 comment(s) | 1108 view(s)
- Historic Window Renovation: 9 comment(s) | 1102 view(s)
- Wood Window Leaks: 2 comment(s) | 1060 view(s)
- Window Repair or Window Replacement?: 7 comment(s) | 947 view(s)
- An Interview with Guardian: 4 comment(s) | 942 view(s)
- Chicago Energy Conservation Code for Dummies: 8 comment(s) | 929 view(s)
- Welcome to Chicago Window Expert: 4 comment(s) | 859 view(s)
- Designing Buildings for the Very Windy City: 11 comment(s) | 796 view(s)
- The Future of Windows: 5 comment(s) | 782 view(s)
- Field Museum Window Replacement: 2 comment(s) | 762 view(s)
- Fixing Window Leaks in Tall Buildings: 4 comment(s) | 762 view(s)
- An Interview with Historic Mike Jackson: 2 comment(s) | 728 view(s)
- Thermal Images of Insulated Glass Types: 2 comment(s) | 670 view(s)
- Leaks and Mold in Walls: the dirty little secret: 1 comment(s) | 625 view(s)
- 2009 Web Statistics Revealed!: 4 comment(s) | 612 view(s)
- The Dynamic Water Test: 3 comment(s) | 575 view(s)
- Wynning in Glass Vegas: 3 comment(s) | 478 view(s)
- Does Chicago Code Require Low-E Glass?: 5 comment(s) | 413 view(s)
- Creating a Leak Survey Form: 4 comment(s) | 408 view(s)
- Choosing a Window Consultant or Exterior Building Consultant: 1 comment(s) | 395 view(s)
- Test Your Mettle at Construction Research Lab: 20 comment(s) | 374 view(s)
- Storm Damage to Windows and Glass: 0 comment(s) | 361 view(s)
- Legal Claims and Disputes in Construction: 0 comment(s) | 358 view(s)
- Performing Window Survey: 0 comment(s) | 324 view(s)
- Chicago Window Expert Goes Solar: 8 comment(s) | 301 view(s)
- An Interview with PPG: 1 comment(s) | 288 view(s)
- Documentary Photos for Curtainwall Survey: 0 comment(s) | 286 view(s)
- Fine Tuning Low-E Glass: 1 comment(s) | 261 view(s)
- Low-E Glass for Cooling Loads: 2 comment(s) | 246 view(s)
- News from the Green Front: 3 comment(s) | 233 view(s)
- Documentary Photos for Window Survey: 0 comment(s) | 226 view(s)
- Drowning Worms? An Olympic Eulogy: 0 comment(s) | 223 view(s)
- Keying for Window Leak Survey: 0 comment(s) | 216 view(s)
- CWE Visits Solar Power Plant: 1 comment(s) | 212 view(s)
- Envision the Wind in a Blizzard: 1 comment(s) | 134 view(s)




Recent Comments